CAMBRIDGE QT Guida di Installazione Pagina 30

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 40
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 29
page 30
the “Simple Network Time Protocol” protocol) or “RTC” (Real Time
Clock).
WARNING: Manually changing the RTC’s time/date via the
“Administration: Date and Time” window should not be attempted
between the hours of 12:00 AM and 2:00 AM on DST transition days
(two per year). Doing so could result in a missed “spring ahead” or
“fall behind” event. Set the date and time before midnight on a DST
transition day or after 2:00 AM on a DST transition day.
If the date is wrong following a power failure, and the system is
relying on the internal real time clock (RTC) and not a network-based
time server, it is likely that the RTC’s battery is depleted. Replace the
battery (see battery replacement, page 14). Reassemble the control
module and then plug it back into the wall outlet. Reset the Real
Time Clock.
Setting Equalizers and Emitter Fault Detection
A special login password is required to gain access to the ENFD
screens. Contact Cambridge Sound Management to obtain the
password(s) for your control module(s). You will need to provide
the Mac Address of each control module. See “Administration:
Networking and Security” for the MAC Address or it can be seen on
the front panel.
Below are the screens for emitter fault detection and equalizer
settings when logged in with the second level password.
Equalizer Update
After logging in with the second level password, the operations
sections will have a block that includes the equalizer settings. The
Masking and Audio equalizers are congured by the factory and
should not need to be modied in most installations. However,
if desired, the equalizers may be used to adjust the system to a
different masking, paging, or music spectrum.
You may specify the gain for a tap in its corresponding box. All values
are measured in dB and the range is +/- 12 dB, in whole number
increments. To specify a negative gain, precede the number by a
minus sign (for example, -2). Once you have specied all of the taps
of interest, press “Submit.” The values will be changed and saved,
and the equalizer will redraw to provide a visual representation of
your settings.
When an equalizer’s settings are modied, the control module
calculates and reports the impact the new settings have on speech
Vedere la pagina 29