Figure 16: Standard view of the ENFD conguration section.
The diagram above shows the window as it appears and is learning
the network conguration.
After the 15 minutes are expired and the system is fully installed, it
is time to enable fault detection if you desire. It is not required for
proper operation. The window shown on the next page shows that
after the 15 minutes have expired there is a dropdown in the upper
right corner that allows 3 actions:
1. Refresh settings - this is used just before enabling ENFD to
make sure any setup data is cleared and proper measurements
will be taken. This can also be used after an error has been xed
and a new test can begin.
2. Enable fault detection - once this is selected, select the zone
in which you want the emitter run monitored, by choosing the
submit button.
3. Disable fault detection - this is used to turn off the feature by
then using the submit button for each run
If there is a fault, an error code 4 will be displayed for that failed zone
in the status block.